SecurityContext

CVE-2011-4055: Siemens Tecnomatix FactoryLink - Buffer Overflow

  • Cve: CVE-2011-4055
  • Name: Siemens Tecnomatix FactoryLink - Buffer Overflow
  • Description: Buffer overflow in the WebClient ActiveX control in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to execute arbitrary code via a long string in a parameter associated with the location URL.
  • Impact: Remote attackers can execute arbitrary code on the affected system, potentially leading to full system compromise.
  • Remediation: Update to the latest version or apply security patches provided by Siemens.
  • Vulnerability type: buffer_overflow
  • Vulnerability impact: remote_code_execution
  • Requirement type: user_interaction
  • Requirements: Victim must visit a malicious webpage
  • Labels source: projectdiscovery
  • Severity: critical
  • Cvss score: 9.3
  • Cvss vector: CVSS:2.0/AV:N/AC:M/Au:N/C:C/I:C/A:C
  • Epss score: 0.04564
  • Epss percentile: 0.91829
  • Assignee: [email protected]
  • Published at: 2012-01-08T00:55:01Z
  • Age in days: 5434
  • Modified at: 2026-06-16T23:34:21Z
  • Patch available: yes
  • References total: 4
  • Products total: 1
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2011-4055
  • Nvd status: modified
  • Checked, none or zero: known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
  • Not known: hackerone

Cwe

IdName
CWE-119Improper Restriction of Operations within the Bounds of a Memory Buffer

References

Same in every row:

  • Source: nvd
UrlTags
http://www.usdata.com/sea/factorylink/en/p_nav5.aspPatch, Vendor Advisory
http://www.us-cert.gov/control_systems/pdf/ICSA-11-343-01.pdfUS Government Resource
http://www.securityfocus.com/bid/51266
https://exchange.xforce.ibmcloud.com/vulnerabilities/72117

Products

ProductAffectedPlatform boundSourcesUrl
siemens:tecnomatix_factorylink= 8.0.2.54, = 7.5.217, = 6.6.1nonvd/v1/products/siemens/tecnomatix_factorylink

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Remote: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, public exploit, public exploit count, initial access, authentication required
  • Not known: known exploited since, vulncheck known exploited since, public exploit first date, nuclei template, initial access since, hackerone reports, exposed hosts