SecurityContext

CVE-2018-25035: Thomson TCW710 - Stored XSS

  • Cve: CVE-2018-25035
  • Name: Thomson TCW710 - Stored XSS
  • Description: A vulnerability, which was classified as problematic, was found in Thomson TCW710 ST5D.10.05. Affected is an unknown function of the file /goform/RGFirewallEL. The manipulation of the argument EmailAddress/SmtpServerName with the input ><script>alert(1)</script> as part of POST Request leads to cross site scripting (Persistent). It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
  • Impact: Attackers can execute arbitrary scripts in the victim's browser, potentially stealing cookies or session tokens.
  • Remediation: Apply the latest firmware update or security patch provided by Thomson.
  • Vulnerability type: stored_xss
  • Vulnerability impact: client_script_exec, information_disclosure
  • Requirement type: user_interaction
  • Requirements: Attacker needs to send a crafted POST request
  • Labels source: projectdiscovery
  • Severity: medium
  • Cvss score: 5.4
  • Cvss vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
  • Epss score: 0.00596
  • Epss percentile: 0.49421
  • Assignee: [email protected]
  • Published at: 2022-06-12T08:15:07Z
  • Age in days: 1625
  • Modified at: 2026-06-17T01:54:34Z
  • Public exploits total: 1
  • References total: 2
  • Products total: 1
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2018-25035
  • Nvd status: modified
  • Checked, none or zero: patch available, known exploited entries, nuclei templates, public exploits capped, oss, projects total, projects, rejected by nvd
  • Not known: hackerone

Cwe

IdName
CWE-80Improper Neutralization of Script-Related HTML Tags in a Web Page
CWE-79Improper Neutralization of Input During Web Page Generation

Public exploits

UrlSourceAdded date
https://alquimistadesistemas.com/auditando-router-thomson-tcw710nvd2022-06-12

References

UrlSourceTags
https://alquimistadesistemas.com/auditando-router-thomson-tcw710nvdExploit, Third Party Advisory
https://vuldb.com/?id.126696nvdThird Party Advisory

Products

ProductAffectedPlatform boundSourcesUrl
technicolor:thomson_tcw710_firmware= st5d.10.05yesnvd/v1/products/technicolor/thomson_tcw710_firmware

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Public exploit: yes
  • Public exploit count: 1
  • Public exploit first date: 2022-06-12
  • Remote: yes
  • Authentication required: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, initial access
  • Not known: known exploited since, vulncheck known exploited since, nuclei template, initial access since, hackerone reports, exposed hosts