CVE-2021-20587: Mitsubishi Electric FA Engineering Software - Buffer Overflow
- Cve: CVE-2021-20587
- Name: Mitsubishi Electric FA Engineering Software - Buffer Overflow
- Description: Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior, and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition on the software products, and possibly to execute a malicious code on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
- Impact: Attackers can cause software crashes or potentially execute malicious code remotely, leading to system disruption or compromise.
- Remediation: Apply the latest patches or updates provided by Mitsubishi Electric for affected software versions.
- Vulnerability type: buffer_overflow
- Vulnerability impact: denial_of_service, remote_code_execution
- Requirement type: none
- Labels source: projectdiscovery
- Severity: critical
- Cvss score: 9.8
- Cvss vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Epss score: 0.03933
- Epss percentile: 0.9064
- Assignee: [email protected]
- Published at: 2021-02-19T20:15:12Z
- Age in days: 2104
- Modified at: 2026-06-17T03:34:03Z
- References total: 6
- Products total: 41
- Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2021-20587
- Nvd status: modified
- Checked, none or zero: patch available, known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
- Not known: requirements, hackerone
Cwe
| Id | Name |
|---|---|
| CWE-122 | Heap-based Buffer Overflow |
| CWE-787 | Out-of-bounds Write |
References
Same in every row:
- Source: nvd
| Url | Tags |
|---|---|
| https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf | Vendor Advisory |
| https://jvn.jp/vu/JVNVU92330101/index.html | Third Party Advisory |
| https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02 | Third Party Advisory, US Government Resource |
| https://jvn.jp/vu/JVNVU92330101 | |
| https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02 | |
| https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2020-021_en.pdf |
Products
Same in every row:
- Platform bound: no
- Sources: nvd
Index
- Checked, none or zero: repositories, repositories high signal, packages
Exploitation
- Remote: yes
- Checked, none or zero: known exploited, known exploited by, exploitation seen, public exploit, public exploit count, initial access, authentication required
- Not known: known exploited since, vulncheck known exploited since, public exploit first date, nuclei template, initial access since, hackerone reports, exposed hosts