CVE-2021-22804: Interactive Graphical SCADA System Data Collector - Path Traversal
- Cve: CVE-2021-22804
- Name: Interactive Graphical SCADA System Data Collector - Path Traversal
- Description: A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
- Impact: Attackers can read arbitrary files on the system, potentially exposing sensitive information.
- Remediation: Apply input validation to restrict file paths and update to the latest version if available.
- Vulnerability type: path_traversal
- Vulnerability impact: file_system_read, information_disclosure
- Requirement type: none
- Labels source: projectdiscovery
- Severity: high
- Cvss score: 7.5
- Cvss vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Epss score: 0.01294
- Epss percentile: 0.71061
- Assignee: [email protected]
- Published at: 2022-02-11T18:15:09Z
- Age in days: 1747
- Modified at: 2026-06-17T03:37:49Z
- Patch available: yes
- References total: 1
- Products total: 1
- Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2021-22804
- Nvd status: modified
- Checked, none or zero: known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
- Not known: requirements, hackerone
Cwe
| Id | Name |
|---|---|
| CWE-22 | Improper Limitation of a Pathname to a Restricted Directory |
References
| Url | Source | Tags |
|---|---|---|
| https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03 | nvd | Patch, Vendor Advisory |
Products
| Product | Affected | Platform bound | Sources | Url |
|---|---|---|---|---|
| schneider-electric:interactive_graphical_scada_system_data_collector | <= 15.0.0.21243 | no | nvd | /v1/products/schneider-electric/interactive_graphical_scada_system_data_collector |
Index
- Checked, none or zero: repositories, repositories high signal, packages
Exploitation
- Remote: yes
- Checked, none or zero: known exploited, known exploited by, exploitation seen, public exploit, public exploit count, initial access, authentication required
- Not known: known exploited since, vulncheck known exploited since, public exploit first date, nuclei template, initial access since, hackerone reports, exposed hosts