SecurityContext

CVE-2022-26507: AT&T Labs Xmill - Heap Buffer Overflow

  • Cve: CVE-2022-26507
  • Name: AT&T Labs Xmill - Heap Buffer Overflow
  • Description: A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
  • Impact: Remote attackers can execute arbitrary code, potentially leading to full system compromise.
  • Remediation: Since the product is no longer supported, consider upgrading to a supported version or applying available patches if possible.
  • Vulnerability type: buffer_overflow
  • Vulnerability impact: remote_code_execution
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: critical
  • Cvss score: 9.8
  • Cvss vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
  • Epss score: 0.02423
  • Epss percentile: 0.84499
  • Assignee: [email protected]
  • Published at: 2022-04-14T13:15:11Z
  • Age in days: 1685
  • Modified at: 2026-06-17T04:35:19Z
  • Patch available: yes
  • References total: 1
  • Products total: 4
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2022-26507
  • Nvd status: modified
  • Checked, none or zero: known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-787Out-of-bounds Write

References

UrlSourceTags
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02nvdMitigation, Release Notes, Third Party Advisory

Products

Same in every row:

  • Sources: nvd
ProductAffectedPlatform boundUrl
att:xmill= 0.7no/v1/products/att/xmill
schneider-electric:ecostruxure_control_expert< 15.1, = 15.1no/v1/products/schneider-electric/ecostruxure_control_expert
schneider-electric:ecostruxure_process_expert< 2021no/v1/products/schneider-electric/ecostruxure_process_expert
schneider-electric:remoteconnectall versionsyes/v1/products/schneider-electric/remoteconnect

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Remote: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, public exploit, public exploit count, initial access, authentication required
  • Not known: known exploited since, vulncheck known exploited since, public exploit first date, nuclei template, initial access since, hackerone reports, exposed hosts