SecurityContext

CVE-2022-46142: Device Storage - Information Disclosure

  • Cve: CVE-2022-46142
  • Name: Device Storage - Information Disclosure
  • Description: Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords.
  • Impact: Attackers with physical access can retrieve and decrypt CLI user passwords, leading to unauthorized access.
  • Remediation: Implement stronger encryption or secure storage mechanisms for CLI passwords, and restrict physical access to devices.
  • Vulnerability type: misconfiguration
  • Vulnerability impact: information_disclosure
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: medium
  • Cvss score: 5.7
  • Cvss vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L
  • Epss score: 0.00279
  • Epss percentile: 0.20618
  • Assignee: [email protected]
  • Published at: 2022-12-13T16:15:25Z
  • Age in days: 1442
  • Modified at: 2026-06-17T05:11:16Z
  • Patch available: yes
  • References total: 2
  • Products total: 101
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2022-46142
  • Nvd status: modified
  • Checked, none or zero: known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-257Storing Passwords in a Recoverable Format
CWE-522Insufficiently Protected Credentials

References

UrlSourceTags
https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdfnvdVendor Advisory
https://cert-portal.siemens.com/productcert/html/ssa-413565.htmlnvd

Products

Same in every row:

  • Platform bound: yes
  • Sources: nvd
ProductAffectedUrl
siemens:scalance_s615_firmwareall versions/v1/products/siemens/scalance_s615_firmware
siemens:scalance_xf204_firmwareall versions/v1/products/siemens/scalance_xf204_firmware
siemens:scalance_m804pb_firmwareall versions/v1/products/siemens/scalance_m804pb_firmware
siemens:scalance_m874-2_firmwareall versions/v1/products/siemens/scalance_m874-2_firmware
siemens:scalance_m874-3_firmwareall versions/v1/products/siemens/scalance_m874-3_firmware
siemens:scalance_m876-3_firmwareall versions/v1/products/siemens/scalance_m876-3_firmware
siemens:scalance_m876-4_firmwareall versions/v1/products/siemens/scalance_m876-4_firmware
siemens:ruggedcom_rm1224_lte(4g)_eu_firmwareall versions/v1/products/siemens/ruggedcom_rm1224_lte(4g)_eu_firmware
siemens:ruggedcom_rm1224_lte(4g)_nam_firmwareall versions/v1/products/siemens/ruggedcom_rm1224_lte(4g)_nam_firmware
siemens:scalance_sc622-2c_firmware< 2.3/v1/products/siemens/scalance_sc622-2c_firmware