SecurityContext

CVE-2023-0595: Schneider Electric EcoStruxure Geo SCADA Expert & ClearSCADA - Improper Output Neutralization for Logs

  • Cve: CVE-2023-0595
  • Name: Schneider Electric EcoStruxure Geo SCADA Expert & ClearSCADA - Improper Output Neutralization for Logs
  • Description: A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)
  • Impact: Malicious packets can cause log misinterpretation, potentially leading to confusion, misdiagnosis, or exploitation based on log data manipulation.
  • Remediation: Update to the latest versions released after October 2022 or apply security patches provided by Schneider Electric.
  • Vulnerability impact: data_tampering
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: medium
  • Cvss score: 5.3
  • Cvss vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
  • Epss score: 0.00417
  • Epss percentile: 0.36738
  • Assignee: [email protected]
  • Published at: 2023-02-24T11:15:10Z
  • Age in days: 1369
  • Modified at: 2026-06-17T05:25:53Z
  • References total: 1
  • Products total: 4
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2023-0595
  • Nvd status: modified
  • Checked, none or zero: patch available, known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
  • Not known: vulnerability type, requirements, hackerone

Cwe

IdName
CWE-117Improper Output Neutralization for Logs
CWE-116Improper Encoding or Escaping of Output

References

UrlSourceTags
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-01.pdfnvd

Products

Same in every row:

  • Platform bound: no
  • Sources: nvd
ProductAffectedUrl
schneider-electric:ecostruxure_geo_scada_expert_2019all versions, = 81.8267.1, = 81.8220.1, = 81.8197.1, = 81.8172.1, = 81.8155.1, = 81.8122.1, = 81.8108.2, = 81.8015.1, = 81.7980.1, = 81.7936.1, = 81.7896.1, = 81.7875.1, = 81.7840.1, = 81.7808.2, = 81.7777.1, = 81.7742.1, = 81.7714.1, = 81.7690.1, = 81.7641.1, = 81.7613.1, = 81.7578.1, = 81.7545.1, = 81.7522.1, = 81.7488.1, = 81.7457.1, = 81.7429.2, = 81.7322.1, = 81.7268.1/v1/products/schneider-electric/ecostruxure_geo_scada_expert_2019
schneider-electric:ecostruxure_geo_scada_expert_2020all versions, = 83.8267.1, = 83.8221.1, = 83.8197.1, = 83.8181.1, = 83.8155.1, = 83.8122.2, = 83.8108.1, = 83.8017.1, = 83.7980.2, = 83.7936.2, = 83.7913.1, = 83.7875.1, = 83.7840.1, = 83.7809.1, = 83.7787.1, = 83.7742.1, = 83.7717.1, = 83.7692.1, = 83.7641.1, = 83.7613.1, = 83.7578.1, = 83.7551.1/v1/products/schneider-electric/ecostruxure_geo_scada_expert_2020
schneider-electric:clearscadaall versions/v1/products/schneider-electric/clearscada
schneider-electric:ecostruxure_geo_scada_expert_2021all versions, = 84.8269.1, = 84.8218.1, = 84.8197.1, = 84.8182.1, = 84.8158.1, = 84.8120.1, = 84.8108.1, = 84.8027.1/v1/products/schneider-electric/ecostruxure_geo_scada_expert_2021

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Remote: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, public exploit, public exploit count, initial access, authentication required
  • Not known: known exploited since, vulncheck known exploited since, public exploit first date, nuclei template, initial access since, hackerone reports, exposed hosts