CVE-2023-23588: SIMATIC IPC - Man-in-the-Middle
- Cve: CVE-2023-23588
- Name: SIMATIC IPC - Man-in-the-Middle
- Description: A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application. A local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit.
- Impact: Local attackers can decrypt and modify traffic between browser and application, potentially leading to data tampering and information disclosure.
- Remediation: Use unique TLS certificates for each installation to prevent man-in-the-middle attacks.
- Vulnerability type: misconfiguration
- Vulnerability impact: man_in_the_middle, information_disclosure, data_tampering
- Requirement type: logged_in
- Requirements: Attacker needs local access to the device
- Labels source: projectdiscovery
- Severity: medium
- Cvss score: 6.3
- Cvss vector: CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N
- Epss score: 0.00092
- Epss percentile: 0.00451
- Assignee: [email protected]
- Published at: 2023-04-11T10:15:18Z
- Age in days: 1323
- Modified at: 2026-06-17T05:37:31Z
- Patch available: yes
- References total: 1
- Products total: 4
- Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2023-23588
- Nvd status: modified
- Checked, none or zero: known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
- Not known: hackerone
Cwe
| Id | Name |
|---|---|
| CWE-200 | Exposure of Sensitive Information to an Unauthorized Actor |
| CWE-295 | Improper Certificate Validation |
References
| Url | Source | Tags |
|---|---|---|
| https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf | nvd | Vendor Advisory |
Products
Same in every row:
- Platform bound: yes
- Sources: nvd
Index
- Checked, none or zero: repositories, repositories high signal, packages
Exploitation
- Authentication required: yes
- Checked, none or zero: known exploited, known exploited by, exploitation seen, public exploit, public exploit count, initial access, remote
- Not known: known exploited since, vulncheck known exploited since, public exploit first date, nuclei template, initial access since, hackerone reports, exposed hosts