SecurityContext

CVE-2024-4064: Tenda AC8 - Buffer Overflow

  • Cve: CVE-2024-4064
  • Name: Tenda AC8 - Buffer Overflow
  • Description: A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
  • Impact: Remote attackers can execute arbitrary code, potentially leading to full device compromise or denial of service.
  • Remediation: Update to the latest firmware version provided by Tenda.
  • Vulnerability type: buffer_overflow
  • Vulnerability impact: remote_code_execution, denial_of_service
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: high
  • Cvss score: 8.8
  • Cvss vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
  • Epss score: 0.01757
  • Epss percentile: 0.78545
  • Assignee: [email protected]
  • Published at: 2024-04-23T20:15:07Z
  • Age in days: 945
  • Modified at: 2026-06-17T08:01:02Z
  • Public exploits total: 1
  • References total: 4
  • Products total: 1
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2024-4064
  • Nvd status: analyzed
  • Checked, none or zero: patch available, known exploited entries, nuclei templates, public exploits capped, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-121Stack-based Buffer Overflow
CWE-787Out-of-bounds Write

Public exploits

UrlSourceAdded date
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.mdnvd2024-04-23

References

Same in every row:

  • Source: nvd
UrlTags
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.mdExploit, Third Party Advisory
https://vuldb.com/?id.261790Third Party Advisory, VDB Entry
https://vuldb.com/?submit.316493Third Party Advisory, VDB Entry
https://vuldb.com/?ctiid.261790Permissions Required, VDB Entry

Products

ProductAffectedPlatform boundSourcesUrl
tenda:ac8_firmware= 16.03.34.09yesnvd/v1/products/tenda/ac8_firmware

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Public exploit: yes
  • Public exploit count: 1
  • Public exploit first date: 2024-04-23
  • Remote: yes
  • Authentication required: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, initial access
  • Not known: known exploited since, vulncheck known exploited since, nuclei template, initial access since, hackerone reports, exposed hosts