CVE-2024-51228: TOTOLINK - Command Injection
- Cve: CVE-2024-51228
- Name: TOTOLINK - Command Injection
- Description: An issue in TOTOLINK-CX-A3002RU V1.0.4-B20171106.1512 and TOTOLINK-CX-N150RT V2.1.6-B20171121.1002 and TOTOLINK-CX-N300RT V2.1.6-B20170724.1420 and TOTOLINK-CX-N300RT V2.1.8-B20171113.1408 and TOTOLINK-CX-N300RT V2.1.8-B20191010.1107 and TOTOLINK-CX-N302RE V2.0.2-B20170511.1523 allows a remote attacker to execute arbitrary code via the /boafrm/formSysCmd component.
- Impact: Remote attackers can execute arbitrary code on the device, potentially leading to full control or compromise of the device.
- Remediation: Update to the latest firmware version provided by TOTOLINK that addresses this vulnerability.
- Vulnerability type: command_injection
- Vulnerability impact: remote_code_execution
- Requirement type: none
- Labels source: projectdiscovery
- Severity: medium
- Cvss score: 6.8
- Cvss vector: CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Epss score: 0.03898
- Epss percentile: 0.90524
- Assignee: [email protected]
- Published at: 2024-11-27T17:15:12Z
- Age in days: 727
- Modified at: 2026-06-17T08:05:31Z
- Public exploits total: 1
- References total: 7
- Products total: 4
- Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2024-51228
- Nvd status: deferred
- Checked, none or zero: patch available, public exploits capped, oss, projects total, projects, rejected by nvd
- Not known: requirements, hackerone
Cwe
| Id | Name |
|---|---|
| CWE-78 | Improper Neutralization of Special Elements used in an OS Command |
Known exploited entries
| List | Added date | Due date | Ransomware use |
|---|---|---|---|
| vulncheck | 2025-10-29 | — | no |
Nuclei templates
| Id | Url |
|---|---|
| CVE-2024-51228 | https://github.com/projectdiscovery/nuclei-templates/blob/main/http/cves/2024/CVE-2024-51228.yaml |
Public exploits
| Url | Source | Added date |
|---|---|---|
| https://github.com/tequilasunsh1ne/CVE_2024_51228.git | vulncheck-xdb | 2024-12-23 |
References
Products
Same in every row:
- Platform bound: no
- Sources: adp_cpes
| Product | Affected | Url |
|---|---|---|
| totolink:a3002ru_firmware | = 1.0.4-B20171106.1512 | /v1/products/totolink/a3002ru_firmware |
| totolink:n150rt_firmware | = 2.1.6-B20171121.1002 | /v1/products/totolink/n150rt_firmware |
| totolink:n300rt_firmware | = 2.1.8-B20191010.1107, = 2.1.8-B20171113.1408, = 2.1.6-B20170724.1420 | /v1/products/totolink/n300rt_firmware |
| totolink:n302re_firmware | = 2.0.2-B20170511.1523 | /v1/products/totolink/n302re_firmware |
Index
- Checked, none or zero: repositories, repositories high signal, packages
Exploitation
- Known exploited by: vulncheck
- Vulncheck known exploited since: 2025-10-29
- Public exploit: yes
- Public exploit count: 1
- Public exploit first date: 2024-12-23
- Authentication required: yes
- Checked, none or zero: known exploited, exploitation seen, initial access, remote
- Not known: known exploited since, initial access since, hackerone reports, exposed hosts