CVE-2024-52571: Teamcenter Visualization & Tecnomatix Plant Simulation - Buffer Overflow
- Cve: CVE-2024-52571
- Name: Teamcenter Visualization & Tecnomatix Plant Simulation - Buffer Overflow
- Description: A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24485)
- Impact: Attackers can execute arbitrary code within the affected application, potentially leading to full system compromise.
- Remediation: Update to the latest versions of the affected applications that include the fix for this vulnerability.
- Vulnerability type: out_of_bounds_rw
- Vulnerability impact: remote_code_execution
- Requirement type: none
- Labels source: projectdiscovery
- Severity: high
- Cvss score: 7.8
- Cvss vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- Epss score: 0.00235
- Epss percentile: 0.14337
- Assignee: [email protected]
- Published at: 2024-11-18T16:15:28Z
- Age in days: 736
- Modified at: 2026-06-17T08:07:28Z
- Patch available: yes
- References total: 2
- Products total: 1
- Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2024-52571
- Nvd status: modified
- Checked, none or zero: known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
- Not known: requirements, hackerone
Cwe
| Id | Name |
|---|---|
| CWE-787 | Out-of-bounds Write |
References
| Url | Source | Tags |
|---|---|---|
| https://cert-portal.siemens.com/productcert/html/ssa-824503.html | nvd | Vendor Advisory |
| https://cert-portal.siemens.com/productcert/html/ssa-645131.html | nvd |
Products
| Product | Affected | Platform bound | Sources | Url |
|---|---|---|---|---|
| siemens:tecnomatix_plant_simulation | >= 2404.0, < 2404.0007; < 2302.0018 | no | nvd | /v1/products/siemens/tecnomatix_plant_simulation |
Index
- Checked, none or zero: repositories, repositories high signal, packages
Exploitation
- Checked, none or zero: known exploited, known exploited by, exploitation seen, public exploit, public exploit count, initial access, remote, authentication required
- Not known: known exploited since, vulncheck known exploited since, public exploit first date, nuclei template, initial access since, hackerone reports, exposed hosts