SecurityContext

CVE-2024-52571: Teamcenter Visualization & Tecnomatix Plant Simulation - Buffer Overflow

  • Cve: CVE-2024-52571
  • Name: Teamcenter Visualization & Tecnomatix Plant Simulation - Buffer Overflow
  • Description: A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24485)
  • Impact: Attackers can execute arbitrary code within the affected application, potentially leading to full system compromise.
  • Remediation: Update to the latest versions of the affected applications that include the fix for this vulnerability.
  • Vulnerability type: out_of_bounds_rw
  • Vulnerability impact: remote_code_execution
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: high
  • Cvss score: 7.8
  • Cvss vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
  • Epss score: 0.00235
  • Epss percentile: 0.14337
  • Assignee: [email protected]
  • Published at: 2024-11-18T16:15:28Z
  • Age in days: 736
  • Modified at: 2026-06-17T08:07:28Z
  • Patch available: yes
  • References total: 2
  • Products total: 1
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2024-52571
  • Nvd status: modified
  • Checked, none or zero: known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-787Out-of-bounds Write

References

UrlSourceTags
https://cert-portal.siemens.com/productcert/html/ssa-824503.htmlnvdVendor Advisory
https://cert-portal.siemens.com/productcert/html/ssa-645131.htmlnvd

Products

ProductAffectedPlatform boundSourcesUrl
siemens:tecnomatix_plant_simulation>= 2404.0, < 2404.0007; < 2302.0018nonvd/v1/products/siemens/tecnomatix_plant_simulation

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Checked, none or zero: known exploited, known exploited by, exploitation seen, public exploit, public exploit count, initial access, remote, authentication required
  • Not known: known exploited since, vulncheck known exploited since, public exploit first date, nuclei template, initial access since, hackerone reports, exposed hosts