SecurityContext

CVE-2024-6207: Rockwell Automation - Denial of Service

  • Cve: CVE-2024-6207
  • Name: Rockwell Automation - Denial of Service
  • Description: CVE 2021-22681 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1550.html and send a specially crafted CIP message to the device. If exploited, a threat actor could help prevent access to the legitimate user and end connections to connected devices including the workstation. To recover the controllers, a download is required which ends any process that the controller is running.
  • Impact: Attackers can prevent access to devices and disconnect connected workstations, leading to service disruption and potential operational downtime.
  • Remediation: Apply security patches provided by Rockwell Automation or update to the latest firmware version.
  • Vulnerability type: denial_of_service
  • Vulnerability impact: denial_of_service
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: high
  • Cvss score: 7.5
  • Cvss vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
  • Epss score: 0.00551
  • Epss percentile: 0.46961
  • Assignee: [email protected]
  • Published at: 2024-10-14T21:15:12Z
  • Age in days: 771
  • Modified at: 2026-06-17T08:17:30Z
  • Patch available: yes
  • References total: 1
  • Products total: 8
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2024-6207
  • Nvd status: analyzed
  • Checked, none or zero: known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-20Improper Input Validation
NVD-CWE-noinfo—

References

UrlSourceTags
https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1707.htmlnvdVendor Advisory

Products

Same in every row:

  • Platform bound: yes
  • Sources: nvd
ProductAffectedUrl
rockwellautomation:controllogix_5580_firmware>= 35.011, < 35.013; >= 34.011, < 34.014; >= 28.011, < 33.017/v1/products/rockwellautomation/controllogix_5580_firmware
rockwellautomation:guardlogix_5580_firmware>= 35.011, < 35.013; >= 34.011, < 34.014; >= 31.011, < 33.017/v1/products/rockwellautomation/guardlogix_5580_firmware
rockwellautomation:compactlogix_5380_firmware>= 35.011, < 35.013; >= 34.011, < 34.014; >= 28.011, < 33.017/v1/products/rockwellautomation/compactlogix_5380_firmware
rockwellautomation:compactlogix_5480_firmware>= 35.011, < 35.013; >= 34.011, < 34.014; >= 32.011, < 33.017/v1/products/rockwellautomation/compactlogix_5480_firmware
rockwellautomation:compact_guardlogix_5380_sil_2_firmware>= 35.011, < 35.013; >= 34.011, < 34.014; >= 31.011, < 33.017/v1/products/rockwellautomation/compact_guardlogix_5380_sil_2_firmware
rockwellautomation:compact_guardlogix_5380_sil_3_firmware>= 35.011, < 35.013; >= 34.011, < 34.014; >= 32.013, < 33.017/v1/products/rockwellautomation/compact_guardlogix_5380_sil_3_firmware
rockwellautomation:controllogix_5580_process_firmware>= 35.011, < 35.013; >= 34.011, < 34.014; >= 33.011, < 33.017/v1/products/rockwellautomation/controllogix_5580_process_firmware
rockwellautomation:factorytalk_logix_echo_firmware>= 35.011, < 35.013; >= 33.011, < 34.014/v1/products/rockwellautomation/factorytalk_logix_echo_firmware

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Remote: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, public exploit, public exploit count, initial access, authentication required
  • Not known: known exploited since, vulncheck known exploited since, public exploit first date, nuclei template, initial access since, hackerone reports, exposed hosts