SecurityContext

CVE-2024-7464: TOTOLINK - Command Injection

  • Cve: CVE-2024-7464
  • Name: TOTOLINK - Command Injection
  • Description: A vulnerability, which was classified as critical, has been found in TOTOLINK CP900 6.3c.566. This issue affects the function setTelnetCfg of the component Telnet Service. The manipulation of the argument telnet_enabled leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-273557 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
  • Impact: Remote attackers can execute arbitrary commands on the device, potentially leading to full system compromise.
  • Remediation: Update to the latest firmware version provided by TOTOLINK or contact vendor for patches.
  • Vulnerability type: command_injection
  • Vulnerability impact: remote_code_execution
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: critical
  • Cvss score: 9.8
  • Cvss vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
  • Epss score: 0.19907
  • Epss percentile: 0.97492
  • Assignee: [email protected]
  • Published at: 2024-08-05T01:16:08Z
  • Age in days: 841
  • Modified at: 2026-06-17T08:20:15Z
  • Public exploits total: 1
  • References total: 4
  • Products total: 1
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2024-7464
  • Nvd status: analyzed
  • Checked, none or zero: patch available, known exploited entries, nuclei templates, public exploits capped, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-77Improper Neutralization of Special Elements used in a Command

Public exploits

UrlSourceAdded date
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/CP900/setTelnetCfg.mdnvd2024-08-05

References

Same in every row:

  • Source: nvd
UrlTags
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/CP900/setTelnetCfg.mdExploit
https://vuldb.com/?ctiid.273557Permissions Required, Third Party Advisory, VDB Entry
https://vuldb.com/?id.273557Permissions Required, Third Party Advisory, VDB Entry
https://vuldb.com/?submit.381334Third Party Advisory, VDB Entry

Products

ProductAffectedPlatform boundSourcesUrl
totolink:cp900_firmware= 6.3c.566yesnvd/v1/products/totolink/cp900_firmware

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Public exploit: yes
  • Public exploit count: 1
  • Public exploit first date: 2024-08-05
  • Remote: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, initial access, authentication required
  • Not known: known exploited since, vulncheck known exploited since, nuclei template, initial access since, hackerone reports, exposed hosts