SecurityContext

CVE-2025-11121: Tenda AC18 - Command Injection

  • Cve: CVE-2025-11121
  • Name: Tenda AC18 - Command Injection
  • Description: A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.
  • Impact: Remote attackers can execute arbitrary commands, potentially leading to full system compromise.
  • Remediation: Update to the latest version.
  • Vulnerability type: command_injection
  • Vulnerability impact: remote_code_execution
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: high
  • Cvss score: 8.8
  • Cvss vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
  • Epss score: 0.03524
  • Epss percentile: 0.8944
  • Assignee: [email protected]
  • Published at: 2025-09-28T22:15:31Z
  • Age in days: 422
  • Modified at: 2026-10-09T09:10:00Z
  • Public exploits total: 1
  • References total: 5
  • Products total: 1
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2025-11121
  • Nvd status: analyzed
  • Checked, none or zero: patch available, known exploited entries, nuclei templates, public exploits capped, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-74Improper Neutralization of Special Elements in Output Used by a Downstream Component

Public exploits

UrlSourceAdded date
https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC18/AdvSetLanip.mdnvd2025-09-28

References

Same in every row:

  • Source: nvd
UrlTags
https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC18/AdvSetLanip.mdExploit, Third Party Advisory
https://vuldb.com/?id.326202Third Party Advisory, VDB Entry
https://vuldb.com/?submit.664191Third Party Advisory, VDB Entry
https://vuldb.com/?ctiid.326202Permissions Required, VDB Entry
https://www.tenda.com.cn/Product

Products

ProductAffectedPlatform boundSourcesUrl
tenda:ac18_firmware= 15.03.05.19yesnvd/v1/products/tenda/ac18_firmware

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Public exploit: yes
  • Public exploit count: 1
  • Public exploit first date: 2025-09-28
  • Remote: yes
  • Authentication required: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, initial access
  • Not known: known exploited since, vulncheck known exploited since, nuclei template, initial access since, hackerone reports, exposed hosts