SecurityContext

CVE-2025-13901: Machine Expert - Denial of Service

  • Cve: CVE-2025-13901
  • Name: Machine Expert - Denial of Service
  • Description: CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.
  • Impact: Unauthenticated attackers can cause partial denial of service by occupying active communication channels.
  • Remediation: Update to the latest version with the fix for improper resource shutdown or release.
  • Vulnerability type: misconfiguration
  • Vulnerability impact: denial_of_service
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: medium
  • Cvss score: 5.3
  • Cvss vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
  • Epss score: 0.00529
  • Epss percentile: 0.45346
  • Assignee: [email protected]
  • Published at: 2026-03-10T18:17:52Z
  • Age in days: 259
  • Modified at: 2026-06-23T14:38:33Z
  • Patch available: yes
  • References total: 1
  • Products total: 3
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2025-13901
  • Nvd status: analyzed
  • Checked, none or zero: known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-404Improper Resource Shutdown or Release

References

UrlSourceTags
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-01.pdfnvdVendor Advisory, Mitigation, Patch

Products

Same in every row:

  • Platform bound: yes
  • Sources: nvd
ProductAffectedUrl
schneider-electric:modicon_m241_firmware< 5.4.13.12/v1/products/schneider-electric/modicon_m241_firmware
schneider-electric:modicon_m251_firmware< 5.4.13.12/v1/products/schneider-electric/modicon_m251_firmware
schneider-electric:modicon_m262_firmware< 5.4.10.12/v1/products/schneider-electric/modicon_m262_firmware

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Remote: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, public exploit, public exploit count, initial access, authentication required
  • Not known: known exploited since, vulncheck known exploited since, public exploit first date, nuclei template, initial access since, hackerone reports, exposed hosts