SecurityContext

CVE-2025-2551: D-Link DIR-618 & 605L - Broken Access Control

  • Cve: CVE-2025-2551
  • Name: D-Link DIR-618 & 605L - Broken Access Control
  • Description: A vulnerability was found in D-Link DIR-618 and DIR-605L 2.02/3.02. It has been classified as problematic. This affects an unknown part of the file /goform/formSetPortTr. The manipulation leads to improper access controls. Access to the local network is required for this attack. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
  • Impact: Attackers can bypass access controls, potentially leading to unauthorized configuration changes or network access.
  • Remediation: No specific fix available; update to the latest supported firmware or replace the device.
  • Vulnerability type: broken_access_control
  • Vulnerability impact: privilege_escalation
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: medium
  • Cvss score: 4.3
  • Cvss vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
  • Epss score: 0.00788
  • Epss percentile: 0.56972
  • Assignee: [email protected]
  • Published at: 2025-03-20T17:15:39Z
  • Age in days: 614
  • Modified at: 2026-06-17T09:07:09Z
  • Public exploits total: 2
  • References total: 6
  • Products total: 2
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2025-2551
  • Nvd status: analyzed
  • Checked, none or zero: patch available, known exploited entries, nuclei templates, public exploits capped, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-266Incorrect Privilege Assignment

Public exploits

UrlSourceAdded date
https://lavender-bicycle-a5a.notion.site/D-Link-DIR-605L-formSetPortTr-1b153a41781f809d95c8e39c6c31c348?pvs=4nvd2025-03-20
https://lavender-bicycle-a5a.notion.site/D-Link-DIR-618-formSetPortTr-1b053a41781f8000a9ded17aa2f587cc?pvs=4nvd2025-03-20

References

Same in every row:

  • Source: nvd
UrlTags
https://lavender-bicycle-a5a.notion.site/D-Link-DIR-605L-formSetPortTr-1b153a41781f809d95c8e39c6c31c348?pvs=4Exploit, Third Party Advisory
https://lavender-bicycle-a5a.notion.site/D-Link-DIR-618-formSetPortTr-1b053a41781f8000a9ded17aa2f587cc?pvs=4Exploit, Third Party Advisory
https://vuldb.com/?id.300165Third Party Advisory, VDB Entry
https://vuldb.com/?submit.516793Third Party Advisory, VDB Entry
https://vuldb.com/?ctiid.300165Permissions Required, VDB Entry
https://www.dlink.com/Product

Products

ProductAffectedPlatform boundSourcesUrl
dlink:dir-605l_firmware= 3.02yesnvd/v1/products/dlink/dir-605l_firmware
dlink:dir-618_firmware= 2.02yesnvd/v1/products/dlink/dir-618_firmware

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Public exploit: yes
  • Public exploit count: 2
  • Public exploit first date: 2025-03-20
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, initial access, remote, authentication required
  • Not known: known exploited since, vulncheck known exploited since, nuclei template, initial access since, hackerone reports, exposed hosts