SecurityContext

CVE-2025-7884: Eluktronics Control Center - Authentication Bypass

  • Cve: CVE-2025-7884
  • Name: Eluktronics Control Center - Authentication Bypass
  • Description: A vulnerability classified as problematic was found in Eluktronics Control Center 5.23.51.41. Affected by this vulnerability is an unknown functionality of the component REG File Handler. The manipulation leads to insufficient verification of data authenticity. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
  • Impact: Local attackers can bypass data authenticity verification, potentially leading to unauthorized data modification or privilege escalation.
  • Remediation: Update to the latest version available from the vendor.
  • Vulnerability type: broken_authentication
  • Vulnerability impact: data_tampering, privilege_escalation
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: high
  • Cvss score: 7.8
  • Cvss vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
  • Epss score: 0.00143
  • Epss percentile: 0.03595
  • Assignee: [email protected]
  • Published at: 2025-07-20T11:15:24Z
  • Age in days: 492
  • Modified at: 2026-06-17T10:05:51Z
  • References total: 3
  • Products total: 1
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2025-7884
  • Nvd status: analyzed
  • Checked, none or zero: patch available, known exploited entries, nuclei templates, public exploits total, public exploits capped, public exploits, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-345Insufficient Verification of Data Authenticity

References

Same in every row:

  • Source: nvd
UrlTags
https://vuldb.com/?id.316999Third Party Advisory, VDB Entry
https://vuldb.com/?submit.611436Third Party Advisory, VDB Entry
https://vuldb.com/?ctiid.316999Permissions Required, VDB Entry

Products

ProductAffectedPlatform boundSourcesUrl
eluktronics:control_center= 5.23.51.41nonvd/v1/products/eluktronics/control_center

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Authentication required: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, public exploit, public exploit count, initial access, remote
  • Not known: known exploited since, vulncheck known exploited since, public exploit first date, nuclei template, initial access since, hackerone reports, exposed hosts