CVE-2026-0581: Tenda AC1206 - Command Injection
- Cve: CVE-2026-0581
- Name: Tenda AC1206 - Command Injection
- Description: A vulnerability was determined in Tenda AC1206 15.03.06.23. Affected by this issue is the function formBehaviorManager of the file /goform/BehaviorManager of the component httpd. Executing a manipulation of the argument modulename/option/data/switch can lead to command injection. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.
- Impact: Remote attackers can execute arbitrary commands, potentially taking full control of the device.
- Remediation: Update to the latest version or apply vendor patches addressing this issue.
- Vulnerability type: command_injection
- Vulnerability impact: remote_code_execution
- Requirement type: none
- Labels source: projectdiscovery
- Severity: critical
- Cvss score: 9.8
- Cvss vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Epss score: 0.09413
- Epss percentile: 0.9549
- Assignee: [email protected]
- Published at: 2026-01-05T09:15:54Z
- Age in days: 323
- Modified at: 2026-06-17T10:10:59Z
- Public exploits total: 1
- References total: 5
- Products total: 1
- Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2026-0581
- Nvd status: analyzed
- Checked, none or zero: patch available, known exploited entries, nuclei templates, public exploits capped, oss, projects total, projects, rejected by nvd
- Not known: requirements, hackerone
Cwe
| Id | Name |
|---|---|
| CWE-74 | Improper Neutralization of Special Elements in Output Used by a Downstream Component |
| CWE-77 | Improper Neutralization of Special Elements used in a Command |
Public exploits
| Url | Source | Added date |
|---|---|---|
| https://github.com/ccc-iotsec/cve-/blob/Tenda/Tenda%20AC1206%E5%91%BD%E4%BB%A4%E6%B3%A8%E5%85%A5%E6%BC%8F%E6%B4%9E.md | nvd | 2026-01-05 |
References
Same in every row:
- Source: nvd
| Url | Tags |
|---|---|
| https://github.com/ccc-iotsec/cve-/blob/Tenda/Tenda%20AC1206%E5%91%BD%E4%BB%A4%E6%B3%A8%E5%85%A5%E6%BC%8F%E6%B4%9E.md | Exploit, Third Party Advisory |
| https://vuldb.com/?id.339473 | Third Party Advisory, VDB Entry |
| https://vuldb.com/?submit.731193 | Third Party Advisory, VDB Entry |
| https://vuldb.com/?ctiid.339473 | Permissions Required, VDB Entry |
| https://www.tenda.com.cn/ | Product |
Products
| Product | Affected | Platform bound | Sources | Url |
|---|---|---|---|---|
| tenda:ac1206_firmware | = 15.03.06.23 | yes | nvd | /v1/products/tenda/ac1206_firmware |
Index
- Checked, none or zero: repositories, repositories high signal, packages
Exploitation
- Public exploit: yes
- Public exploit count: 1
- Public exploit first date: 2026-01-05
- Remote: yes
- Checked, none or zero: known exploited, known exploited by, exploitation seen, initial access, authentication required
- Not known: known exploited since, vulncheck known exploited since, nuclei template, initial access since, hackerone reports, exposed hosts