SecurityContext

CVE-2026-1689: Tenda HG10 - Command Injection

  • Cve: CVE-2026-1689
  • Name: Tenda HG10 - Command Injection
  • Description: A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used.
  • Impact: Remote attackers can execute arbitrary commands, potentially taking full control of the device.
  • Remediation: Update to the latest version or apply vendor patches.
  • Vulnerability type: command_injection
  • Vulnerability impact: remote_code_execution
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: high
  • Cvss score: 7.3
  • Cvss vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
  • Epss score: 0.03107
  • Epss percentile: 0.88109
  • Assignee: [email protected]
  • Published at: 2026-01-30T17:16:13Z
  • Age in days: 298
  • Modified at: 2026-06-17T10:16:19Z
  • Public exploits total: 2
  • References total: 6
  • Products total: 1
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2026-1689
  • Nvd status: analyzed
  • Checked, none or zero: patch available, known exploited entries, nuclei templates, public exploits capped, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-74Improper Neutralization of Special Elements in Output Used by a Downstream Component

Public exploits

UrlSourceAdded date
https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.mdnvd2026-01-30
https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.md#pocnvd2026-01-30

References

Same in every row:

  • Source: nvd
UrlTags
https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.md#pocExploit
https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.mdExploit, Third Party Advisory
https://vuldb.com/?id.343483Third Party Advisory, VDB Entry
https://vuldb.com/?submit.741411Third Party Advisory, VDB Entry
https://vuldb.com/?ctiid.343483Permissions Required, VDB Entry
https://www.tenda.com.cn/Product

Products

ProductAffectedPlatform boundSourcesUrl
tenda:hg10_firmwareall versionsyesnvd/v1/products/tenda/hg10_firmware

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Public exploit: yes
  • Public exploit count: 2
  • Public exploit first date: 2026-01-30
  • Remote: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, initial access, authentication required