SecurityContext

CVE-2026-4008: Tenda W3 - Buffer Overflow

  • Cve: CVE-2026-4008
  • Name: Tenda W3 - Buffer Overflow
  • Description: A flaw has been found in Tenda W3 1.0.0.3(2204). This issue affects some unknown processing of the file /goform/wifiSSIDset of the component POST Parameter Handler. Executing a manipulation of the argument index/GO can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
  • Impact: Remote attackers can execute arbitrary code, potentially leading to full system compromise.
  • Remediation: Update to the latest version.
  • Vulnerability type: buffer_overflow
  • Vulnerability impact: remote_code_execution
  • Requirement type: none
  • Labels source: projectdiscovery
  • Severity: high
  • Cvss score: 8.8
  • Cvss vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
  • Epss score: 0.00722
  • Epss percentile: 0.54933
  • Assignee: [email protected]
  • Published at: 2026-03-12T07:16:18Z
  • Age in days: 257
  • Modified at: 2026-06-17T10:55:50Z
  • Public exploits total: 2
  • References total: 7
  • Products total: 1
  • Advisory url: https://nvd.nist.gov/vuln/detail/CVE-2026-4008
  • Nvd status: analyzed
  • Checked, none or zero: patch available, known exploited entries, nuclei templates, public exploits capped, oss, projects total, projects, rejected by nvd
  • Not known: requirements, hackerone

Cwe

IdName
CWE-119Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE-787Out-of-bounds Write

Public exploits

UrlSourceAdded date
https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-w3-formwrlSSIDset-go-buffer-overflownvd2026-03-12
https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-w3-formwrlSSIDset-index-buffer-overflownvd2026-03-12

References

Same in every row:

  • Source: nvd
UrlTags
https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-w3-formwrlSSIDset-go-buffer-overflowExploit, Third Party Advisory
https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-w3-formwrlSSIDset-index-buffer-overflowExploit, Third Party Advisory
https://vuldb.com/?id.350531Third Party Advisory, VDB Entry
https://vuldb.com/?submit.769182Third Party Advisory, VDB Entry
https://vuldb.com/?submit.769183Third Party Advisory, VDB Entry
https://vuldb.com/?ctiid.350531Permissions Required, VDB Entry
https://www.tenda.com.cn/Product

Products

ProductAffectedPlatform boundSourcesUrl
tenda:w3_firmware= 1.0.0.3(2204)yesnvd/v1/products/tenda/w3_firmware

Index

  • Checked, none or zero: repositories, repositories high signal, packages

Exploitation

  • Public exploit: yes
  • Public exploit count: 2
  • Public exploit first date: 2026-03-12
  • Remote: yes
  • Authentication required: yes
  • Checked, none or zero: known exploited, known exploited by, exploitation seen, initial access
  • Not known: known exploited since, vulncheck known exploited since, nuclei template, initial access since, hackerone reports, exposed hosts